Formula details
Product Details
Overview
Critical Applications in Battery Lifecycle
Are micro-scale defects compromising your cell safety before production even begins? In the high-stakes world of battery manufacturing, relying on destructive physical cross-sectioning often destroys the very evidence you need to analyze. At Jeenoce, we engineer our High-Resolution X-ray Micro-CT System for Battery R&D and Failure Analysis to solve this fundamental challenge. By integrating Non-destructive Testing (NDT) directly into the lifecycle, we empower engineers to visualize internal structures without altering the specimen's integrity.
Material R&D & Characterization
Developing next-generation chemistries requires absolute clarity on internal microstructures. Our systems provide voxel-level battery material characterization, allowing researchers to quantify critical metrics that define cell performance.
- Porosity & Tortuosity: Accurately map pore networks to optimize electrolyte wetting and ion transport.
- Particle Integrity: Visualize active material particle cracking during cycling to assess electrode durability.
- Phase Distribution: Utilize high-contrast imaging to distinguish between binders, conductive additives, and active materials.
Failure Analysis (Root Cause Identification)
When a cell fails, identifying the exact mechanism is non-negotiable. Our Micro-CT solutions serve as the definitive tool for Internal Short Circuit Root-Cause Analysis, moving beyond symptoms to identify the structural origin of failure.
- Dendrite Visualization: Detect early-stage Lithium Dendrite Growth before it penetrates the separator.
- Contaminant Detection: Locate metallic particles that cause self-discharge using advanced Metal Artifact Reduction (MAR) algorithms.
- Structural Integrity: Inspect Solid-state electrolyte micro-cracks or separator deformation that standard X-ray inspection might miss.
Process Validation
Transitioning from lab-scale prototypes to mass production introduces variability. We deploy Sub-micron Voxel Resolution Imaging to validate assembly precision and ensure manufacturing tolerances are met.
- Alignment Checks: Perform precise Anode-Cathode Overhang Measurement to prevent lithium plating at cell edges.
- Winding Inspection: Conduct Jelly-roll Deformation Analysis to detect telescoping or buckling caused by improper winding tension.
- Tab Welding: Verify the integrity of tab-to-electrode connections non-destructively, ensuring robust electrical continuity.
Advanced Technology & Imaging Capabilities

At Jeenoce, we engineer our High-Resolution X-ray Micro-CT System for Battery R&D and Failure Analysis to see what others miss. We don't just provide a scanner; we provide the clarity needed to validate new chemistries and ensure safety. Our systems leverage industrial-grade components designed for the specific density challenges of lithium-ion cells.
The X-Ray Source
The heart of our system is a high-stability micro-focus X-ray tube. To achieve Sub-micron Voxel Resolution Imaging, stability is non-negotiable. Our source maintains a consistent focal spot size even during long scans, ensuring that geometric magnification does not compromise sharpness. This allows engineers to clearly visualize Active material particle cracking and measure Anode-Cathode Overhang with micron-level accuracy, regardless of the battery casing material.
The Detector
We utilize high-dynamic-range Flat Panel Detectors (FPD) optimized for high energy. Standard detectors struggle with the contrast between light materials (like separators) and dense metals (like copper current collectors). Our detectors are calibrated for Phase-contrast X-ray Imaging capabilities, allowing for distinct Voxel-level battery material characterization. This ensures that soft tissue structures, such as the separator or electrolyte distribution, are visible alongside the metallic components.
4D In-Situ Capabilities
Static images only tell half the story. Our systems support 4D In-situ Electrochemical CT Scanning, enabling researchers to observe internal changes over time while the battery is cycling.
- Real-time Monitoring: Watch Lithium Dendrite Growth Visualization as it happens under electrical load.
- Structural Evolution: Track Jelly-roll Deformation Analysis during charging and discharging cycles.
- Thermal Dynamics: Identify structural precursors to failure before a thermal event occurs.
This capability transforms the equipment from a simple inspection tool into a dynamic research partner. For labs looking to scale this level of analysis into a production environment, we can also integrate these imaging systems into broader custom automation workflows, ensuring seamless data flow from the lab bench to the factory floor.
Software & AI-Driven Analysis

Great hardware is only half the battle; the real magic happens when you can actually interpret the massive datasets a Micro-CT scan generates. We have integrated advanced software capabilities directly into our workflow to turn raw X-ray data into actionable insights for battery development.
Reconstruction Algorithms
Getting a clean image from a scan of a dense battery cell is challenging due to metal artifacts. Our system utilizes proprietary Metal Artifact Reduction (MAR) algorithms to clean up the noise caused by high-density cathode materials and current collectors. This ensures that the resulting 3D volume is sharp and accurate, allowing you to see the true structure of the jelly-roll without the streaking that often obscures critical defects. We also employ iterative reconstruction techniques that maintain high image quality even when scanning speeds are increased for higher throughput.
AI Defect Recognition
Manually inspecting thousands of layers in a CT scan is impossible for a human operator to do consistently. We leverage Automated Defect Recognition (ADR) software powered by deep learning models specifically trained on battery architectures. This AI assistant automatically flags anomalies such as:
- Electrode overhang misalignment
- Particle cracking in active materials
- Foreign metal contaminants
- Tab welding defects
This automation transforms failure analysis from a subjective, time-consuming task into a reliable, quantitative process.
Voxel-Level Segmentation
To truly understand performance, you need to quantify the internal microstructure. Our software performs voxel-based material segmentation, allowing you to digitally separate the anode, cathode, separator, and casing. This capability is essential for electrode tortuosity and porosity characterization, enabling R&D teams to calculate the exact volume fractions and surface areas of active materials. By isolating specific phases, you can visualize and measure issues like lithium dendrite growth or solid-state electrolyte micro-cracks with sub-micron precision.
For labs that also handle electronics alongside batteries, our software suite shares DNA with our high-precision BGA X-ray inspection equipment, ensuring a familiar and robust interface for complex defect analysis across different device types.
Technical Specifications: High-Resolution X-ray Micro-CT System
At Jeenoce, we engineer our imaging systems to meet the exacting standards of Industry 4.0, delivering the sub-micron precision required for advanced battery analysis. Our equipment is designed with a modular architecture, allowing for scalable configurations that transition seamlessly from R&D laboratories to automated production lines.
We prioritize data integrity and operational safety, ensuring our systems integrate flawlessly with your existing MES and ERP infrastructures. Below are the core technical capabilities of our Micro-CT / Nano-CT systems.
| Specification Category | Performance Capability |
|---|---|
| X-Ray Tube Voltage | High-power transmission optimized for penetrating high-density battery casings and electrode stacks. |
| Min. Voxel Resolution | Sub-micron accuracy (Nano-CT capable) for visualizing micro-cracks and electrode particle distribution. |
| Geometric Magnification | Flexible stage positioning allows for high geometric magnification essential for detailed defect analysis. |
| Sample Weight Capacity | Robust manipulator design supports various form factors, from coin cells to larger pouch and prismatic cells. |
| Scan Time | AI-driven tool-path optimization and IoT sensors reduce cycle times for high-throughput environments. |
| Safety Compliance | Fully shielded cabinet design compliant with international radiation safety standards. |
Our commitment extends beyond hardware; we provide comprehensive technical services to ensure your system maintains peak calibration and safety compliance throughout its lifecycle. By leveraging real-time process monitoring and AI-driven analytics, we empower manufacturers to achieve flawless manufacturing tolerances and maximize ROI.
The Jeenoce Advantage – From Lab to Line
At Jeenoce, we understand that moving from a controlled R&D environment to high-volume manufacturing is one of the biggest challenges in the battery industry. Our High-Resolution X-ray Micro-CT Systems are designed not just as standalone lab instruments, but as scalable components of a larger intelligent manufacturing ecosystem. We bridge the gap between initial prototype analysis and mass production quality control.
Why Jeenoce?
We don't just sell equipment; we provide integrated solutions. Our expertise lies in connecting advanced inspection hardware with broader production data systems. By leveraging our experience in Turnkey Line Integration, we ensure that the detailed structural data captured during micro-CT scanning isn't siloed. Instead, it feeds directly into your manufacturing execution systems (MES), enabling smarter decision-making and continuous process improvement.
Scalability and Modular Design
Our systems are built with modularity at their core. Whether you are running a small-scale pilot line or ramping up for gigafactory-level output, our equipment grows with you. The modular architecture supports rapid scaling, allowing you to increase throughput without overhauling your entire inspection infrastructure. This flexibility is critical for maintaining consistent quality standards as production volumes surge.
Customization for Specific Needs
We know that no two battery production lines are identical. We offer tailored implementations to match your specific operational requirements. From adjusting the physical footprint of the machine to integrating custom software algorithms for specific defect recognition, we work closely with you to maximize operational efficiency and ROI. Our commitment to value-driven outcomes means we configure our technology to solve your unique production bottlenecks, ensuring seamless integration into your existing workflow.
Case Study: Detecting Thermal Runaway Precursors in High-Nickel NCM Cells
We partnered with a tier-one battery manufacturer facing reliability challenges with their latest High-Nickel NCM cells. The primary objective was to identify microscopic structural instabilities that act as precursors to thermal runaway, without destroying the sample during testing. Leveraging the same high-precision imaging architecture found in our Micro-CT / Nano-CT systems for semiconductor applications, we deployed a customized scanning protocol to visualize internal defects at a sub-micron level.
Our analysis focused on three critical failure modes:
- Active Material Particle Cracking Visualization: The system successfully captured the initiation of micro-cracks within the cathode material after limited cycling, highlighting stress points that standard 2D inspection missed.
- Jelly-Roll Deformation Analysis: Through voxel-level 3D reconstruction, we identified subtle buckling in the jelly-roll structure, a direct result of uneven swelling pressure.
- Electrode Delamination: We detected early-stage separation between the active material and the current collector, allowing the client to adjust their binder formulation.
By utilizing this thermal runaway precursor structural inspection, the client was able to validate their process changes immediately. This transition from reactive failure analysis to proactive design optimization demonstrates our commitment to delivering value-driven outcomes that enhance safety and product longevity.
Service, Support & Training
Deploying a High-Resolution X-ray Micro-CT System for Battery R&D and Failure Analysis is a significant investment, and at Jeenoce, we ensure you get maximum value from day one. We do not just supply hardware; we act as your strategic partner in turnkey laboratory setup and commissioning, ensuring your facility is ready for Industry 4.0 standards.
Turnkey Installation & Integration
Our team manages the entire deployment process. We handle the physical installation and the digital integration of the CT system into your existing infrastructure. Whether you are setting up a standalone R&D unit or integrating into a smart factory environment, we ensure seamless connectivity with your MES and ERP systems for real-time data flow.
Expert Training & Knowledge Transfer
To leverage the full potential of sub-micron voxel resolution imaging, your team needs expert guidance. We provide hands-on training covering:
- Operational Safety: Proper handling of X-ray sources and compliance protocols.
- Data Analysis: Mastering reconstruction algorithms and automated defect recognition (ADR) software.
- Maintenance: Basic troubleshooting to minimize downtime.
Global After-Sales Support
We offer localized R&D equipment preventive maintenance to keep your system running at peak precision. Our global support network ensures that whether you need a recalibration or a software update, assistance is readily available. You can easily coordinate service schedules or request immediate technical support through our contact page.



